Whatsapp:+8613388587272

Email:[email protected]

en.pngEN
All Categories
sidebanner

Battey Cable

Home>Product>Power Conductor Cable>Battey Cable

4
2
1
4
2
1

EN 50618 Solar Cable

Feature:
INQUIRY
DESCRIPTION
APPLICATION
These cables are designed for connecting photovoltaic system components inside and outside of buildings and equipment with high mechanical requirements and extreme weather conditions.
Standards:
2PfG 1169/08.2007 (PV1-F), TUV certificate, RHOS.
Description
Electrical Properties
» Rated Voltage U0/U: 0.6/1 kV AC; 0.9/1.5 kV DC
» Maximum Permitted DC Voltage: 1.8 kV DC (conductor/conductor, non earthed system, circuit not under load)
» Insulation Resistance: 1000 MΩ-km
» Spark Test: 6000 Vac (8400 Vdc)
» Voltage Withstand: 6500 Vac for 5 min
Thermal Properties
» Maximum Voltage: Ambient Temperature: -40℃ ~ +90℃
» Maximum Temperature At Conductor: 120℃ (20000h) according to IEC/EN 60216-1
» Short Circuit Temperature: 200℃/5 sec
» Thermal Endurance Test: According to EN 60216-2 (temperature index +120° C)
» High Temperature Pressure Test: According to EN 60811-3-1
» Damp-Heat Resistance: According to EN 60068-2-78 with 85% humidity
Mechanical Properties
» Minimum Bending Radius: 4×OD (fixed), 5×OD (flexing)
» Dynamic Penetration: According to 2 PfG 1169/08.2007 Annex F
» Notch Propagation: According to 2 PfG 1169/08.2007 Annex G
» Tensile Strength And Elongation Of Insulation And Jacket: According to EN 60811
» Anticipated Period Of Use: 25 years
Chemical Properties
» Ozone Resistance: According to EN 50396 part 8.1.3 Method B
» Weathering- UV Resistance: According to HD 605/A1
» Ammoniac resistant
» Very good resistance to oils and chemicals
» High wear and robust, abrasion resistant
» Acid & Alkaline Resistance: According to EN 60811-2-1 (Oxal acid and sodium hydroxide)
Fire Performance
» Flame retardant according to EN 50265-2-1, IEC 60332-1, VDE 0482-332-1-2, DIN EN 60332-1-2
» Low smoke emission according to IEC 61034, EN 50268
» Halogen free according to EN 50267-2-1, IEC 60754-1
» Low corrosivity of gases according to EN 50267-2-2, IEC 60754-2


CONSTRUCTION
Conductor:
Stranded tinned copper conductor per DIN VDE 0295 and IEC 60228 Class 5
Insulation:
Electron beam cross-linked, halogen free and flame retardant compound
Sheath:
Electron beam cross-linked, halogen free and flame retardant compound, Black


PARAMETER
Dimensions and Weight
NO. OF CORES 
×NOMINAL CROSS 
SECTION
NO. OF 
STRANDING
NOMINAL CONDUCTOR DIAMETERNOMINAL INSULATION THICKNESSNOMINAL SHEATH 
THICKNESS
NOMINAL OVERALL 
DIAMATER
NOMINAL 
WEIGHT
NO. ×MM²-MMMMMMMMKG/KM
1×1.530/0.251.581.140.825.452
1×2.550/0.252.041.140.825.867
1×4.056/0.302.591.140.826.487
1×6.084/0.303.171.140.827.0113
1×1078/0.404.071.520.828.6178
1×16128/0.405.221.520.829.8254
1×25199/0.406.511.520.8211.1363
1×35279/0.407.711.520.8212.3473


Contact Us