Whatsapp:+8613388587272

Email:[email protected]

en.pngEN
All Categories
sidebanner

Battey Cable

Home>Product>Power Conductor Cable>Battey Cable

2
2

MV-90/105 XLPE Insulation Type 5kV-46kV, Copper Wire Shield Cable

Feature:
INQUIRY
DESCRIPTION
APPLICATION
Primary power and distribution circuits in industrial and commercial installations, power circuits in generating plants where line to ground fault current are within shield capabilities. May be used in wet or dry locations, installed in underground, duct, or direct burial.
Standards:
UL 1072 Medium Voltage Power Cables. 
ICEA S-94-649 5 kV – 46 kV Shielded Power Cables.
AEIC CS8 Standard for Utility Shielded Power Cables Rated 5 kV – 46 kV.
Specifications
Maximum operating voltage: 
• 5 kV to 46 kV 100% and 133% IL Maximum conductor operation temperatures: 
Wet and dry locations 
• Normal: 105 °C 
• Emergency: 140 °C 
• Short Circuit: 250 °C
Optional
1. Sealed conductor with strand filled compound passes the production water penetration tests per ICEA-T-31-610 at 15 psi for 60 minutes.
2. Dual sealed cable (Strand Filled on conductor and Neutral wires) meets the water penetration requirements in accordance with ICEA-T-34-664.
SPECIFICATIONS
Medium Voltage
Medium Voltage
CONSTRUCTION
Conductor:
Soft annealed uncoated copper compressed Class B per ASTM B496 or hard drawn Aluminum-1350 compressed Class B per ASTM B400.
Conductor Shield:
Semi conducting cross-linked polyethylene compound (XLPE compound).
Insulation:
Thermoset crosslinked polyethylene (XLPE). or TR-XLPE.
Insulation Shield:
Semi conducting cross-linked polyethylene compound (XLPE compound).
Metallic Shield:
Solid soft annealed copper wires per ASTM B3, helically applied and uniformly spaced. Or copper tape shield.
Jacket:
Extruded to fill, Black sunlight resistant linear low density polyethylene (LLDPE), with three Red Stripes. Or PVC.
PARAMETER
5kV TR-XLPE Insulation type
8kV TR-XLPE Insulation type
15kV TR-XLPE Insulation type
25kV TR-XLPE insulation type
35kV XLPE insulated
Size AWGNumber of  StrandsNominal OD Over Insulation1/3 NeutralFull Neutral
orNumber of  WiresSizeJacket ThicknessApproximate Outside DiameterApproximate Net WeightNumber of  WiresSizeJacket ThicknessApproximate Outside DiameterApproximate Net Weight
kcmil
inAWGmilinlb/kftAWGmilinlb/kft
Copper 100% Insulation Level (90 mil)
270.5614500.814691614500.81589
1190.54714500.845471312500.88730
1/0190.58914500.886531612500.92870
2/0190.631114500.9377913105011089
3/0190.681414500.989411610501.051309
4/0190.731814501.031146169501.141613
250370.791312501.121340
350370.891812501.231785
500371.021710501.422535
750611.21209801.73731
1000611.36269801.854807
Aluminum 100% Insulation Level (90 mil)
210.48614500.783111014500.78360
270.5614500.813251014500.81374
1190.54614500.843551314500.84439
1/010.54614500.853701614500.85491
1/0190.58614500.883891614500.88510
2/0190.62714500.934441312500.96629
3/0190.67914500.985191612501.01738
4/0190.731114501.036061310501.11921
250370.791314501.096861610501.171071
350370.891814501.19879169501.291356
500371.021612501.3812082910501.421823
750611.221510801.691798
1000611.37169801.862292


Contact Us