In free air, raceways or direct burial
In wet or dry locations
Permitted for use in Class I, Division 2 industrial hazardous locations per NEC
Permitted for Exposed Run (ER) use in accordance with NEC
DESCRIPTION
APPLICATION
Standards:
Industry Compliances:
UL 44 Type XHHW-2, UL 1277 Type TC, TC-ER, UL 1581, ICEA S-95-658/NEMA WC70
Flame Test Compliances: UL 1581/UL 2556 VW-1
UL 44 Type XHHW-2, UL 1277 Type TC, TC-ER, UL 1581, ICEA S-95-658/NEMA WC70
Flame Test Compliances: UL 1581/UL 2556 VW-1
Features
Rated at 90˚C wet or dry
Ripcord applied to all cables with jacket thickness of 60 mils or less
Abrasion and chemical resistant
Excellent electrical properties
Sunlight and weather resistant
Ripcord applied to all cables with jacket thickness of 60 mils or less
Abrasion and chemical resistant
Excellent electrical properties
Sunlight and weather resistant

SPECIFICATIONS

UV Resistance

Working Temperature 90℃

Flame Retardant
CONSTRUCTION

- Conductor:14 AWG thru 750 kcmil bare, annealed copper per ASTM B3 Class B stranding per ASTM B8.
- Insulation:Flame-retardant Cross-linked Polyethylene (XLPE) Color-coded per ICEA Method 4; individual conductors colored black with conductor number surface printed in contrasting ink.
- Ground:Uninsulated bare annealed copper per ASTM B3 Class B stranding per ASTM B8.
- Jacket:Lead-free, flame-retardant, sunlight-resistant Polyvinyl Chloride (PVC).
PARAMETER
- TC Tray Cable FR-XLPE/PVC
| Insulation Thickness | Min. Avg. Jacket Thickness | NOMINAL CABLE O.D. | ||||||
| number of Cond. | Cond. Size (AWG) | Cond. Strand. | Ground Wire Size (AWG) | IN | MM | IN | MM | IN |
| 14 AWG - 750 kcmil MULTI-CONDUCTORS | ||||||||
| 3 | 14 | 7/.0242 | 14 | 0.030 | 0.76 | 0.045 | 1.14 | 0.390 |
| 3 | 12 | 7/.0305 | 12 | 0.030 | 0.76 | 0.045 | 1.14 | 0.435 |
| 3 | 10 | 7/.0385 | 10 | 0.030 | 0.76 | 0.060 | 1.52 | 0.485 |
| 3 | 8 | 7/.0486 | 10 | 0.045 | 1.14 | 0.060 | 1.52 | 0.640 |
| 4 | 8 | 7/.0486 | 10 | 0.045 | 1.14 | 0.060 | 1.52 | 0.705 |
| 3 | 6 | 7/.0612 | 8 | 0.045 | 1.14 | 0.060 | 1.52 | 0.720 |
| 4 | 6 | 7/.0612 | 8 | 0.045 | 1.14 | 0.060 | 1.52 | 0.790 |
| 3 | 4 | 7/.0772 | 8 | 0.045 | 1.14 | 0.080 | 2.03 | 0.875 |
| 4 | 4 | 7/.0772 | 8 | 0.045 | 1.14 | 0.080 | 2.03 | 0.950 |
| 3 | 2 | 7/.0974 | 6 | 0.045 | 1.14 | 0.080 | 2.03 | 1.000 |
| 4 | 2 | 7/.0974 | 6 | 0.045 | 1.14 | 0.080 | 2.03 | 1.095 |
| 3 | 1 | 19/.0664 | 6 | 0.055 | 1.40 | 0.080 | 2.03 | 1.120 |
| 4 | 1 | 19/.0664 | 6 | 0.055 | 1.40 | 0.080 | 2.03 | 1.235 |
| 3 | 1/0 | 19/.0745 | 6 | 0.055 | 1.40 | 0.080 | 2.03 | 1.215 |
| 4 | 1/0 | 19/.0745 | 6 | 0.055 | 1.40 | 0.080 | 2.03 | 1.340 |
| 3 | 2/0 | 19/.0837 | 6 | 0.055 | 1.40 | 0.080 | 2.03 | 1.310 |
| 4 | 2/0 | 19/.0837 | 6 | 0.055 | 1.40 | 0.080 | 2.03 | 1.450 |
| 3 | 3/0 | 19/.0940 | 4 | 0.055 | 1.40 | 0.080 | 2.03 | 1.420 |
| 4 | 3/0 | 19/.0940 | 4 | 0.055 | 1.40 | 0.080 | 2.03 | 1.570 |
| 3 | 4/0 | 19/.1055 | 4 | 0.055 | 1.40 | 0.080 | 2.03 | 1.540 |
| 4 | 4/0 | 19/.1055 | 4 | 0.055 | 1.40 | 0.110 | 2.79 | 1.765 |
| 3 | 250 | 37/.0822 | 4 | 0.065 | 1.65 | 0.110 | 2.79 | 1.750 |
| 4 | 250 | 37/.0822 | 4 | 0.065 | 1.65 | 0.110 | 2.79 | 1.930 |
| 3 | 350 | 37/.0973 | 3 | 0.065 | 1.65 | 0.110 | 2.79 | 1.970 |
| 4 | 350 | 37/.0973 | 3 | 0.065 | 1.65 | 0.110 | 2.79 | 2.180 |
| 3 | 500 | 37/.1162 | 2 | 0.065 | 1.65 | 0.110 | 2.79 | 2.250 |
| 4 | 500 | 37/.1162 | 2 | 0.065 | 1.65 | 0.110 | 2.79 | 2.475 |
| 3 | 750 | 61/.1109 | 1 | 0.080 | 2.03 | 0.140 | 3.56 | 2.810 |
| 4 | 750 | 61/.1109 | 1 | 0.080 | 2.03 | 0.140 | 3.56 | 3.115 |
Contact Us
Related Product
EPDM Insulated and Lead Sheathed, Galvanized Steel Strip Armoring, Flat Cable for Submersible Oil Pump
EPDM insulated and Lead sheath, double galvanized steel armor, With 2×3/8CT(2205) ESP Cable (Flat)
EPDM Insulation and Lead Sheath with Tube Covered with Single Galvanized Steel Armor ESP Cable
Nonmetallic-Sheathed Cable Type NM-B
EN
AR
PT
KO
DE
TR
FR