DESCRIPTION
OVERVIEW
For use in fixed installations in industrial areas, buildings and similar applications.
Standard and Approval:
BS6724
Technical Characteristics:
Flame retardant: BS EN 60332-1-2, BS EN 60332-3-24
Colour of sheath: black
Core identification: HD 308 S2
Other colors available at customer request
2-core: brown, blue
3-core: brown, black, grey
4-core: blue, brown, black, grey
5-core: green-yellow, blue, brown, black, grey
auxiliary cables: white with black numbering
Maximum conductor operating temperature: +90°C
Lowest ambient temperature for fixed installation: -40°C
Lowest installation temperature: 0°C
Maximum short-circuit conductor temperature: +250°C
Smoke emission: BS EN 61034-2
Corrosive and acid gas emission: BS EN 60754-1, HCL ≤ 0,5%
Minimum bending radius: 6 x D for cables with circular copper
conductors D – overall diameter of the cable
Test voltage: 3.5kV
Colour of sheath: black
Core identification: HD 308 S2
Other colors available at customer request
2-core: brown, blue
3-core: brown, black, grey
4-core: blue, brown, black, grey
5-core: green-yellow, blue, brown, black, grey
auxiliary cables: white with black numbering
Maximum conductor operating temperature: +90°C
Lowest ambient temperature for fixed installation: -40°C
Lowest installation temperature: 0°C
Maximum short-circuit conductor temperature: +250°C
Smoke emission: BS EN 61034-2
Corrosive and acid gas emission: BS EN 60754-1, HCL ≤ 0,5%
Minimum bending radius: 6 x D for cables with circular copper
conductors D – overall diameter of the cable
Test voltage: 3.5kV

SPECIFICATIONS

Low Voltage

LSZH

Working Temperature 90℃

Cold Resistant -40℃

Flame Retardant
CONSTRUCTION
- Conductor:annealed copper conductor or aluminium conductor, circular compacted stranded class 2 acc. to BS EN 60228
- Insulation:cross-linked polyethylene XLPE type GP8 acc. to BS 7655-1.3
- Bedding:LSOH (special low smoke zero halogen compound)
- Armour:single layer of galvanized steel wires applied spirally over the bedding (SWA)
- Sheath:LSOH compound type LTS1 acc. to BS 7655-6.1
PARAMETER
- 2 Cores
- 3 Cores
- 4 Cores
- 5 Cores
Conductor Size (mm2) | Nominal Insulation Thickness(mm2) | Nominal Overall Diameter (mm) | Approximate net weight of cu cables(kg/km) | Maximum copper conductor resistance at temperature 20°C | Approximate net weight of al cables(kg/km) | Maximum copper Al conductor resistance at temperature 20°C | ||
| 2 | × | 1.5 | 0.7 | 14.5 | 339 | 12.100 | 321 | - |
| 2 | × | 2.5 | 0.7 | 15.4 | 388 | 7.410 | 358 | - |
| 2 | × | 4 | 0.7 | 16.48 | 452 | 4.610 | 403 | - |
| 2 | × | 6 | 0.7 | 17.56 | 526 | 3.080 | 452 | - |
| 2 | × | 10 | 0.7 | 19.94 | 786 | 1.830 | 663 | 3.08 |
| 2 | × | 16 | 0.7 | 21.94 | 981 | 1.150 | 786 | 1.91 |
| 2 | × | 25 | 0.9 | 25.84 | 1441 | 0.727 | 1135 | 1.2 |
| 2 | × | 35 | 0.9 | 24.73 | 1539 | 0.524 | 1112 | 0.868 |
| 2 | × | 50 | 1 | 27.25 | 1935 | 0.387 | 1324 | 0.641 |
| 2 | × | 70 | 1.1 | 30.17 | 2446 | 0.268 | 1592 | 0.443 |
| 2 | × | 95 | 1.1 | 35.02 | 3364 | 0.193 | 2204 | 0.32 |
| 2 | × | 120 | 1.2 | 37.53 | 3968 | 0.153 | 2503 | 0.253 |
| 2 | × | 150 | 1.4 | 40.88 | 4733 | 0.124 | 2902 | 0.206 |
| 2 | × | 185 | 1.6 | 45.83 | 6050 | 0.099 | 3794 | 0.164 |
| 2 | × | 240 | 1.7 | 50.01 | 7361 | 0.075 | 4435 | 0.125 |
| 2 | × | 300 | 1.8 | 54.39 | 8813 | 0.060 | 5154 | 0.1 |
| 2 | × | 400 | 2 | 60.03 | 11071 | 0.047 | 6193 | 0.0778 |