Type MC Cable is suitable for use as follows:
•Branch, feeder and service power distribution in commercial, industrial, institutional, and multi-residential buildings.
•Power, lighting, control, and signal circuits.
•Fished or embedded in plaster.
•Concealed or exposed installations.
•Environmental air-handling spaces per NEC 300.22 (C).
•Places of Assembly per NEC 518.4 and theaters per NEC 520.5.
•Installation in cable tray and approved raceways.
•Under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2).
•Class I Div. 2, Class II Div 2, & Class III Div. 1 Hazardous Locations.
Standards & References
Type MC Cable meets or exceeds the requirements of the following
•UL 83
•UL 1569
•UL 1685
•Federal Specification A-A59544 (formerly J-C-30B)
•FT4/IEEE 1202 (70,000 Btu/hr) Vertical Cable Tray Flame Test
•NEC
•Listed for use in UL 1, 2 and 3 Hour Through Penetration Firestop Systems

Type MC Cable is constructed with soft-drawn copper, Type THHN/THWN conductors rated 90°C dry available in sizes 14 AWG through 2 AWG, and a green insulated grounding conductor. The conductors are cabled together and a binder tape bearing the print legend is wrapped around the assembly. Aluminum interlocking armor is applied over the assembly.
Features
•Reduces installation costs up to 50% over pipe and wire.
•Lightweight aluminum armor--as much as 45% lighter than steel MC Cable.
•UL Classified 1, 2, and 3 hour Through Penetration Firestop Systems: W-J-3037, W-L-3110, W-L-3113, W-L-3117, W-L-3120, W-L-3121, W-L-3160, C-AJ-3115, C-AJ-3140, C-AJ-3142, C-AJ-3145, C-AJ-3173, C-AJ-3202, C-AJ-4065, C-AJ-4066, F-C-3038.
•Cable reverse wound on reel for ease of pulling and installation. When pulling from coils, pull from inside to ensure ease of installation.
•Anti-short bushings are not required for use with MC cable per the NEC and UL
SPECIFICATIONS
Low Voltage
Low Voltage
Working Temperature 90℃
Working Temperature 90℃
Fire Resistance
Fire Resistance
CONSTRUCTION
Lightweight Aluminum Interlocked Armor. 600 Volts. Copper Power Conductors. THHN/THWN Insulated Singles. Green Insulated Grounding Conductor. Sizes 14 AWG through 2 AWG. Rated VW-1.
PARAMETER
MC Cable With THHN Ground
Conductor Size+ (AWG)Solid or StrandedGrounding Conductor Size (AWG) and StrandingOverall Diameter (inches)Weight (lbs./1000ft.)
Ampacity (Amps)





60℃75℃90℃
14-2Solid14-10.433100151515
12-2Solid12-10.469129202020
12-3Solid12-10.501157202020
12-4Solid12-10.537187202020
10-2Solid10-10.537181303030
10-3Solid10-10.577225303030
10-4Solid10-10.622270303030
8-3710-70.706320405055
8-4710-70.754408405055
6-378-70.785471556575
6-478-70.862580556575